P:\INSTALLATION INST\SWITCH KITS\INST-S6000-ATS.vsd REV - 04-12 Page 1
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com
INSTALLATION INSTRUCTIONS
S6000-ATS ANTI-TAMPER SWITCH KIT
Electrical Specifications:
WHT = COM
YEL = N/O
ORG = N/C
5AMPS @ 250V
Resistive
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: service@sdcsecurity.com
Insert Anti-Tamper Switch
where shown.
Insert the S6000-ATS Assy. into the device. Slide the End Cap over the
End Cap Bracket. Position the S6000-ATS Assy so the switch arm
makes contact and is activated by the inside surface of the End Cap.
Hold the S6000-ATS Assy. in place as you slide out the End Cap.
Tighten the set screws on the S6000-ATS to lock it in place.
Once S6000-ATS Switch Assembly is properly located, wire
the switch and re-install the Device Cover and End Cap.
END CAP
Switch Arm
Remove
Device Cover
and End Cap.
DEVICE
COVER
END CAP
END CAP
BRACKET